Mode |
THHS |
|||
Quantity of hammer |
Increase or decrease according to customer needs |
|||
Air hammer control circuit |
Each hammer has a separate control circuit |
|||
Hammer position |
It can be adjusted inX,Y and Z,and the adjustment range can be customized according to requirements |
|||
Air usage for a single air hammer |
1m/min |
|||
Characteristic |
Air pressure (bar) |
4Bar |
5Bar |
6Bar |
Frequency (Hertz) |
20.5 |
23 |
25 |
|
Frequency (hits/minute) |
1230 |
1380 |
1500 |
|
Air consumption(lmin) |
814 |
922 |
928 |
|
Characteristic |
The single hammering function is suitable for castings with simple sand core structure and easy sand discharge |
|||
Note |
Develop &design according to the customer's requirements |